title: Propylene Glycol Freezing Point and Burst Protection
description: Freeze protection keeps glycol pumpable. Burst protection just keeps pipes intact. See the propylene glycol concentration each winter system needs.
image: https://info.kellerheartt.com/hubfs/propylene%20glycol%20freezing%20point_%20%281%29.jpg
---

[![keller-heartt-oil](https://info.kellerheartt.com/hubfs/branding/keller-heartt-logo.200.png)](https://www.kellerheartt.com/)

- Shop By Industry
  
    - [Trucking & Automotive](https://www.kellerheartt.com/collections/commercial-truck-supplies) 
          - [Diesel Exhaust Fluid](https://www.kellerheartt.com/collections/diesel-exhaust-fluid)
          - [Motor Oil](https://www.kellerheartt.com/collections/motor-oil)
          - [Brake Cleaner](https://www.kellerheartt.com/collections/brake-cleaner)
          - [Antifreeze](https://www.kellerheartt.com/collections/antifreeze-coolants)
          - [Transmission Fluid](https://www.kellerheartt.com/collections/transmission-fluid)
    - [Machine Shops & Metalworking](https://www.kellerheartt.com/collections/metalworking-fluids) 
          - [Cutting Oil](https://www.kellerheartt.com/collections/cutting-oil)
          - [Coolant](https://www.kellerheartt.com/collections/tool-die-coolants)
          - [Hydraulic Oil](https://www.kellerheartt.com/collections/hydraulic-oil)
          - [Soluble Oil](https://www.kellerheartt.com/collections/soluble-oil)
          - [Rust Preventative](https://www.kellerheartt.com/collections/tool-die-rust-veto)
    - [Industrial](https://www.kellerheartt.com/collections/industrial-products) 
          - [Hydraulic Oil](https://www.kellerheartt.com/collections/hydraulic-oil)
          - [Industrial Gear Oil](https://www.kellerheartt.com/collections/industrial-gear-oil-all-sizes-brands)
          - [Multi-Purpose Grease](https://www.kellerheartt.com/collections/multi-purpose-grease)
          - [Cleaner & Degreaser](https://www.kellerheartt.com/collections/industrial-cleaners-descalers-degreasers)
          - [Ethylene Glycol](https://www.kellerheartt.com/collections/ethylene-glycol)
    - [Food & Beverage](https://www.kellerheartt.com/collections/food-grade-oils-lubricants) 
          - [Propylene Glycol](https://www.kellerheartt.com/collections/propylene-glycol-drums)
          - [Cassida Fluid & Grease](https://www.kellerheartt.com/collections/cassida-lubricants-greases)
          - [Fuchs Gear Oil & Grease](https://www.kellerheartt.com/collections/fuchs-lubricants)
- Shop By Brand
  
    - [Shell Products](https://www.kellerheartt.com/collections/shell-oil-lubricants)
    - [TRUEGARD Products](https://www.kellerheartt.com/collections/truegard-oil-lubricants)
    - [Blue DEF Products](https://www.kellerheartt.com/collections/bluedef)
    - [Oil Eater Products](https://www.kellerheartt.com/collections/oil-eater)
- [Blog](https://info.kellerheartt.com/blogs)
- [Request a Quote](https://www.kellerheartt.com/pages/request-a-quote)

[Contact Us](https://www.kellerheartt.com/pages/contact-us)

Propylene Glycol

# Freeze Protection vs. Burst Protection: What Your Glycol Concentration Prevents

[Brian McGrath](https://info.kellerheartt.com/blogs/author/brian-mcgrath)

 Nov 24, 2026

---

Freeze protection and burst protection aren't the same thing, and the glycol concentration that delivers one won't always deliver the other. Freeze protection keeps your fluid fully liquid and pumpable at the coldest temperature you expect. Burst protection only keeps pipes and coils from splitting while the fluid turns to slush. At 0°F, that's the difference between 37.7% propylene glycol and 25.1%.

Below, we break down both thresholds, show the propylene glycol freezing point at common concentrations, and match the right protection to HVAC loops, geothermal systems, heated sidewalks, and food-contact chillers.

## Key Takeaways:

- Freeze protection keeps glycol pumpable. Burst protection only prevents pipe rupture.
- 0°F takes 37.7% propylene glycol for freeze protection but 25.1% for burst protection.
- Keller-Heartt recommends staying at or above 25% glycol so inhibitors work and bacteria stay out.
- Systems that must run in the cold need freeze protection.

## What's the Difference Between Freeze Protection and Burst Protection?

Freeze protection means the fluid won't form ice crystals at your lowest expected temperature, so pumps can keep moving it. Burst protection means the fluid may turn to slush, but it won't expand enough to crack pipes, as long as the system has room for that expansion.

### Definitions:

Freeze protection: The glycol concentration at which a water-glycol mix stays free of ice crystals and fully pumpable at a given temperature.

Burst pipe protection: The concentration at which the mix may form slush but won't expand enough to rupture pipes, coils, or heat exchangers.

Why the gap? As a glycol mix cools past its freezing point:

- Water crystallizes out first
- The fluid left behind gets richer in glycol
- You end up with slush instead of a solid block of expanding ice

That slush can't flow through a pump, but it also won't split a copper line.

In 2020, Dow's glycol market developer Daniel Cohen laid out the rule of thumb in ChemPoint's[DOWFROST Dan: Freeze & Burst Protection](https://www.chempoint.com/insights/dowfrost-dan-freeze-and-burst-protection): set your freezing point at least 5°F below the lowest ambient temperature you expect. That margin covers:

- Sensor error
- Wind chill on exposed piping
- The cold snap nobody forecast

## What Is the Propylene Glycol Freezing Point at Each Concentration?

The [propylene glycol](https://www.kellerheartt.com/collections/propylene-glycol-drums)freezing point drops as concentration rises. Roughly 19% propylene glycol gives freeze protection to 20°F, 38% gets you to 0°F, and 57% reaches -40°F. Burst protection takes noticeably less glycol at every temperature.

The figures below come from Dow's typical DOWFROST concentrations, published in the same[ChemPoint freeze and burst protection guide](https://www.chempoint.com/insights/dowfrost-dan-freeze-and-burst-protection) (updated in 2026). Percentages are by volume.

| Propylene Glycol Concentration for Freeze vs. Burst Protection |  |  |
| --- | --- | --- |
| Lowest Expected Temp (°F) | Freeze Protection (% PG by volume) | Burst Protection (% PG by volume) |
| 20 | 18.8 | 12.6 |
| 10 | 30.4 | 20.9 |
| 0 | 37.7 | 25.1 |
| -10 | 44.0 | 29.3 |
| -20 | 48.2 | 31.4 |
| -30 | 52.4 | 34.6 |
| -40 | 56.5 | 36.6 |
| -50 | 59.7 | 36.6 |
| -60 | 62.8 | 36.6 |

Note: Several numbers in that table fall below 25%. They'll protect against freezing or bursting, but they're too dilute for the long haul. More on that below.

## Why Does Burst Protection Stop Needing More Glycol Around 37%?

Several concentrations in this table fall below 25%. While they may meet the freeze or burst protection threshold, Keller-Heartt recommends staying at or above 25% glycol to support inhibitor performance and help prevent microbial growth. For another reference when choosing your mix, see our [Propylene Glycol Concentration & Freeze Point Chart](https://www.kellerheartt.com/pages/propylene-glycol-concentration-chart).

| Our take: For a system that sits idle through winter, there's rarely a reason to go much past the mid-30s. RL Deppmann's 2016 guide,[Selecting the Proper Glycol Concentration for Closed-Loop HVAC Systems](https://www.deppmann.com/blog/service-tip-of-the-month/selecting-proper-concentration-glycol/), lands in the same place, recommending about 35% propylene glycol for burst protection. Filling a dormant loop with 50/50 buys freeze protection you won't use and costs you efficiency every hour the system runs the rest of the year. |
| --- |

## Which Type of Protection Does Your System Need?

If the fluid has to circulate at the coldest temperature, or the system has no room for expansion, you need freeze protection. If the system can sit dormant through a cold snap and has room for slush to expand, burst protection is enough.

The deciding question is simple: does this loop need to run when it's coldest?

| Glycol Protection by Winter Application |  |  |
| --- | --- | --- |
| System | Protection Needed | Why |
| HVAC loop that runs all winter | Freeze | Fluid must pump at the lowest temperature |
| HVAC loop that sits idle in winter | Burst | Dormant, with room for slush to expand |
| Geothermal ground loop | Freeze (25% minimum) | Runs in heating mode all winter, often below 32°F |
| Heated sidewalks and snowmelt | Freeze | Must start up during the coldest conditions |
| Food-contact chiller loop | Freeze | Runs continuously below water's freezing point |

### HVAC and Chilled-Water Loops

How an HVAC loop runs in winter decides what it needs:

- **Burst protection**: chilled-water loops that shut down for the season
- **Freeze protection**: rooftop units, outdoor air handlers, and year-round process loops, sized to your design low plus 5°F
- **Freeze protection**: "idle" loops that may have to restart after a power or pump failure in January

### Geothermal Loops

Ground source heat pump loops run cold fluid all winter, which puts them squarely in freeze protection territory. Dow's technical bulletin, [Why a Minimum 25% Glycol Concentration Is Recommended in GSHP Applications](https://dow.com/documents/180/180-01562-01-geothermal-ground-source-heat-pumps-gshp-dowfrost-hd-heat-transfer-fluid.pdf.html), addresses the common practice of dropping to 20% to save on fluid. Dow's conclusion is that the savings aren't worth the risk of total system failure and fluid replacement.

### Heated Sidewalks and Snowmelt Systems

Snowmelt systems sit idle until snow hits, which makes them look like a burst protection job. They aren't. The whole point is to start pumping during the worst weather of the year, often after a deep overnight low, so the fluid has to be liquid on demand. Size these for freeze protection at your design low.

### Food-Contact Chiller Loops in Breweries and Food Plants

Glycol jackets on fermenters, brite tanks, and process chillers typically run below 32°F around the clock. For these loops:

- **Protection type**: freeze protection, sized to the chiller's lowest setpoint plus margin
- **Fluid type**: food-grade propylene glycol, since these loops sit right next to product
- How it's used: our guide to[propylene glycol in food and beverage operations](https://info.kellerheartt.com/blogs/propylene-glycol-in-food) covers breweries, wineries, and processors
- Still choosing a glycol? See our breakdown of[ethylene glycol vs. propylene glycol](https://info.kellerheartt.com/blogs/ethylene-glycol-vs.-propylene-glycol)

## Can You Use Too Much Glycol?

Yes. Glycol beyond what your application needs makes the fluid thicker and worse at moving heat. That means:

- Pumps work harder
- Your chiller or boiler runs longer
- You spend more on fluid

Running 50/50 everywhere "just to be safe" feels responsible, but is it buying you anything on a loop that sits idle all winter?

Going too low causes a different set of problems. According to Dow's GSHP bulletin:

- At or above 25%, glycol inhibits the growth of most microbes and fungi
- Below 25%, propylene glycol can become a food source that bacteria break down
- Dow's inhibitors perform best between 25% and 60% glycol, so corrosion protection can fall short under 25%

| Our take: Pick the lowest concentration that clears your target temperature, and never go below 25%, even in a mild climate. That's why a 20°F burst protection number like 12.6% looks great on paper but doesn't belong in a real system. |
| --- |

Get ahead of the first cold snap.   
TRUEGARD 960 is an inhibited, food-grade propylene glycol concentrate you dilute to the exact protection your system needs.<https://www.kellerheartt.com/products/truegard-hale-guard-960-propylene-glycol-inhibited-fluid-100-concentrate-55-gallon-drum>

[Shop the TRUEGARD 960 55-gallon drum →](https://www.kellerheartt.com/products/truegard-hale-guard-960-propylene-glycol-inhibited-fluid-100-concentrate-55-gallon-drum)

## How Do You Check Your Glycol Concentration Before Winter?

Test it with a glycol refractometer before the first hard freeze, then compare the reading to your target from the table above. It takes a few minutes, and it's the only way to know what's really in the loop after a year of leaks, top-offs, and service work.

1. **Pull a representative sample**. Draw from a point with good circulation, not a fill port you just topped off.
2. **Use a propylene glycol scale**. Propylene and ethylene glycol read differently, so make sure your refractometer is set for PG.
3. **Compare to your target**. Use the freeze or burst protection number for your design low, and don't forget the 25% floor.
4. Adjust in the right direction. If you're low, add concentrate. For routine top-offs, use a premix like[TRUEGARD 905 50/50](https://www.kellerheartt.com/collections/propylene-glycol-drums/products/truegard-hale-guard-905-food-grade-propylene-glycol-50-50-55-gallon-drum) instead of plain water.
5. **Check inhibitor condition**. Follow the product data sheet for pH or inhibitor testing, since freeze protection can be fine while corrosion protection fades.

Plain makeup water quietly weakens glycol systems. Every gallon of water added after a leak repair dilutes the loop's propylene glycol concentration, which lowers both freeze and burst protection. Testing with a PG-scale refractometer before winter, and topping off with premixed glycol instead of water, keeps protection where it was designed.

Wondering how TRUEGARD stacks up against the big-name brand? See our[TRUEGARD propylene glycol vs. DOWFROST comparison](https://info.kellerheartt.com/blogs/comparing-truegard-propylene-glycol-vs-dowfrost).

## How Do You Choose the Right Glycol Concentration?

Freeze protection keeps glycol moving. Burst protection keeps pipes in one piece. The right concentration depends on which one your system needs and how cold it gets where you are:

- **Need freeze protection**: loops that run in winter, including geothermal, snowmelt, and food-contact chillers
- **Can use burst protection**: dormant loops with room for expansion
- **Either way**: stay at or above 25%

Not sure where your system lands?[Talk with our team](https://www.kellerheartt.com/pages/contact-us), and we'll help you pick the right ratio before the cold sets in.

### Frequently Asked Questions About Glycol Freeze and Burst Protection

### What is the freezing point of 50% propylene glycol?

A 50% propylene glycol mix provides freeze protection to roughly -24°F. 48.2% for -20°F and 52.4% for -30°F. Burst protection at 50% extends far lower. Always confirm against your specific product's temperature chart, since inhibitor packages vary.

### Is 30% propylene glycol enough for winter?

It depends on whether the system has to run. About 30% propylene glycol gives burst protection to roughly -10°F, but freeze protection only to about 10°F. That's fine for an idle loop in a moderate climate, but not for a system that must pump during a deep cold snap.

### Do I need food-grade propylene glycol for a brewery chiller?

If there's any chance of incidental contact with product, food-grade propylene glycol is the standard choice for breweries, wineries, and food plants. Jacketed fermenters and process chillers run right next to what you're making. Our guide on [when food-grade propylene glycol is required](https://info.kellerheartt.com/blogs/when-is-food-grade-propylene-glycol-required) covers the details.

### How often should I test glycol concentration?

Keller-Heartt recommends testing at least once a year, ideally before the first hard freeze, and again after any leak repair, drain-down, or top-off. Concentration drifts as makeup water gets added.

### Can I mix propylene glycol and ethylene glycol?

We don’t recommend it. Mixing the two makes concentration readings unreliable, may combine inhibitor packages that weren't designed to work together, and eliminates the safety benefit of propylene glycol in food or occupied spaces. If you're switching types, drain and flush first. Our [ethylene glycol vs. propylene glycol](https://info.kellerheartt.com/blogs/ethylene-glycol-vs.-propylene-glycol) guide explains the tradeoffs.

### Does adding water to a glycol system reduce freeze protection?

Yes. Every gallon of plain water dilutes the loop and raises its freezing point. For top-offs, Keller-Heartt recommends premixed glycol at your target concentration, and a retest after any significant addition.

[Propylene Glycol](https://info.kellerheartt.com/blogs/tag/propylene-glycol)

#### FOLLOW AND SHARE:

[![share on facebook](https://info.kellerheartt.com/hs-fs/hubfs/images/social/icons/facebook-color.png?width=45&height=45&name=facebook-color.png)](https://www.facebook.com/pages/Keller-Heartt-Company/170082969671892?ref=hl) [![follow us on youtube](https://info.kellerheartt.com/hs-fs/hubfs/images/social/icons/youtube-color.png?width=45&height=45&name=youtube-color.png)](https://www.youtube.com/channel/UCA9e_Yo_qd4PqpK2dDdgxaw) [![follow us on instagram](https://info.kellerheartt.com/hs-fs/hubfs/images/social/icons/instagram-color.png?width=45&height=45&name=instagram-color.png)](https://www.instagram.com/keller.heartt/?hl=en) [![follow us on twitter](https://info.kellerheartt.com/hs-fs/hubfs/images/social/icons/twitter-color.png?width=45&height=45&name=twitter-color.png)](https://twitter.com/KellerHeartt) [![follow us on linkedin](https://info.kellerheartt.com/hs-fs/hubfs/images/social/icons/linkedin-color.png?width=45&height=45&name=linkedin-color.png)](https://www.linkedin.com/company/keller-heartt-oil/)

[Shop by Brand ►](https://www.kellerheartt.com/collections/shop-by-brand)

## Similar posts

<https://info.kellerheartt.com/blogs/ice-making-made-better-with-propylene-glycol>

Propylene Glycol

### [Ice Making Made Better With Propylene Glycol](https://info.kellerheartt.com/blogs/ice-making-made-better-with-propylene-glycol)

Propylene glycol is critical for good ice making. Learn about the types of glycol, the best water-to-glycol ratio, and how to save by buying in bulk.

 Brian McGrath  Aug 25, 2023

<https://info.kellerheartt.com/blogs/comparing-truegard-propylene-glycol-vs-dowfrost>

Coolant

### [Comparing Truegard® Propylene Glycol Vs. Dowfrost™](https://info.kellerheartt.com/blogs/comparing-truegard-propylene-glycol-vs-dowfrost)

Truegard® Propylene Glycol is an affordable alternative to DOWFROST™. Here are some of the advantages of going with TRUEGARD from Keller-Heartt.

 Brian McGrath  Jul 14, 2023

<https://info.kellerheartt.com/blogs/propylene-glycol-in-food>

Propylene Glycol

### [The Versatile Applications of Propylene Glycol in Food & Beverage Operations](https://info.kellerheartt.com/blogs/propylene-glycol-in-food)

How food-grade propylene glycol keeps our favorite foods fresh, tasty, and safe—plus why it’s the behind-the-scenes hero in food and beverage...

 Brian McGrath  Jul 29, 2025

## **Get the latest oil & lubricant industry insights**

Subscribe to the Keller-Heartt blog so you can sharpen your industry knowledge, gather helpful tips, and stay informed about changes or updates in the oil provider landscape.

### Subscribe to Our Blog!

© 2025 Keller-Heart Oil All rights reserved

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Brian McGrath",
    "url" : "https://info.kellerheartt.com/blogs/author/brian-mcgrath"
  },
  "dateModified" : "2026-11-24T21:09:48.909Z",
  "datePublished" : "2026-11-24T21:08:15.000Z",
  "headline" : "Propylene Glycol Freezing Point and Burst Protection",
  "image" : [ "https://info.kellerheartt.com/hubfs/propylene%20glycol%20freezing%20point_%20%281%29.jpg" ],
  "mainEntityOfPage" : {
    "@id" : "https://info.kellerheartt.com/blogs/propylene-glycol-freezing-point",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://info.kellerheartt.com/hubfs/branding/keller-heartt-logo.350.png"
    },
    "name" : "Keller-Heartt Co"
  }
}
```